Large-Size Structure Life & Static Test Complex

This facility is intended for static and repeated static (fatigue) structural strength tests. The complex enables applying external forces to provide load/strain conditions for tested structures simulating realistic service environment.

Reinforced floor size

48 х 24 m

Allowable unit load on the reinforced floor

4·105 N/m2

Bearing capacity of the reinforced ceiling

4,8·10N

Reinforced bridge capacity

4·106 N

Total number of the reinforced bridges

23

Bearing capacity of the reinforced wall panels

1,2·10N/m

Number of the reinforced wall panels

3

Number of the loading channels

50

Force range of the hydraulic load actuators


(2 – 500)·104 N.

Комплекс ресурсных и статических испытаний крупногабаритных конструкций

Load frequency:

  • multi-channel 1Hz
  • single-channel 3Hz

Number of the sampled sensors:

  • strain gauges 4000
  • crack sensors 100
  • deflection sensors 20